JINGE CM3 (M3) series transparent molded case circuit breaker is a new-generation high-performance industrial MCCB designed for global power distribution and motor protection. Compliant with IEC 60947-2 and GB 14048.2 standards, it covers rated current from 63A up to 800A and operates safely at AC 400V power systems.
With a compact structure, high breaking capacity, stable thermo-magnetic tripping and durable mechanical life, CM3 provides full protection against overload, short circuit and under-voltage faults. The transparent housing enables intuitive internal status inspection, fast troubleshooting and higher on-site safety, making it an ideal choice for modern industrial control, construction, data centers and infrastructure projects.
| Model | Frame Current | Voltage | Application |
|---|---|---|---|
| CM3-63 | 63A | AC 400V | Light distribution, small equipment |
| CM3-100 | 100A | AC 400V | Workshop, small building |
| CM3-225 | 225A | AC 400V | Commercial power, small industry |
| CM3-400 | 400A | AC 400V | Industrial distribution |
| CM3-630 | 630A | AC 400V | Heavy equipment, main line |
| CM3-800 | 800A | AC 400V | Large power distribution |
| Item | CM3-63 | CM3-100 | CM3-225 | CM3-400 | CM3-630 | CM3-800 |
|---|---|---|---|---|---|---|
| Frame Current Inm (A) | 63 | 100 | 225 | 400 | 630 | 800 |
| Rated Current In (A) | (6),10,16,20,25,32,40,50,63 | 10,16,20,32,40,50,63,80,100 | 100,125,160,180,200,225 | 225,250,315,350,400 | 400,500,630 | 630,700,800 |
| Rated Insulation Voltage Ui (V) | 500 | 690 | 800 | 690 | 690 | 690 |
| Rated Operating Voltage Ue (V) | 400 | 400 | 230/400 | 400 | 400 | 400 |
| Rated Impulse Withstand Voltage Uimp (kV) | 6 | 6 | 8 | 6 | 6 | 6 |
| No. of Poles | 3/4 | 3/4 | 2/3/4 | 3/4 | 3/4 | 3/4 |
| Breaking Class | L/M | L/M | L/M/H | L/M | L/M | L/M |
| Ultimate Breaking Capacity Icu (kA) AC400V | 10/15/35 | 35/50 | 35/50/65 | 45/65 | 45/65 | 50/65 |
| Service Breaking Capacity Ics (kA) AC400V | 5/10/25 | 25/30 | 25/30/50 | 22.5/32.5 | 22.5/32.5 | 25/32.5 |
| Arc Flash Distance (mm) | ≤50 | ≤50 | ≤50 | ≤100 | ≤100 | ≤100 |
| Operating Cycles / Hour | 120 | 120 | 120 | 60 | 60 | 20 |
| Mechanical Life With Load | 4000 | 3000 | 3000 | 1500 | 1500 | 1000 |
| Mechanical Life No Load | 6000 | 7000 | 7000 | 6500 | 6500 | 4000 |
| Tripping Type | Thermal-magnetic | Thermal-magnetic | Thermal-magnetic | Thermal-magnetic | Thermal-magnetic | Thermal-magnetic |
| Protection Class | IP30 | IP30 | IP30 | IP30 | IP30 | IP30 |
| Standards | GB14048.2, IEC60947-2 | GB14048.2, IEC60947-2 | GB14048.2, IEC60947-2 | GB14048.2, IEC60947-2 | GB14048.2, IEC60947-2 | GB14048.2, IEC60947-2 |
JINGE CM3 transparent MCCB is widely used in industrial power distribution, factory production lines, motor control centers, pump and compressor protection, commercial building power supply, construction engineering, data center auxiliary power systems and infrastructure projects.
With high reliability, easy maintenance and modern transparent design, CM3 is particularly suitable for high-standard projects requiring frequent inspection, stable performance and long service life. It is the preferred new-generation MCCB for global electrical distributors, engineering contractors and system integrators.