Address
304 North Cardinal St.
Dorchester Center, MA 02124
Work Hours
Monday to Friday: 7AM - 7PM
Weekend: 10AM - 5PM
The SG10 series epoxy resin dry-type power transformer is a new-generation product with the highest safety performance. All insulating materials are non-combustible, self-extinguishing and non-toxic, with combustible content less than 10% of traditional epoxy cast products, and no toxic fumes generated during long-term combustion at 800℃.
This product shows outstanding advantages in power, subway, shipbuilding, chemical, metallurgy and other scenarios with high safety requirements, high humidity and poor ventilation. Its special coil design, technology and materials achieve excellent three-proof performance (moisture-proof, mildew-proof, salt-fog-proof), can withstand thermal shock, and ensures zero cracking and zero partial discharge.With a new structure, materials and technology, the SG10 series features excellent heat dissipation, long thermal life and strong overload capacity, capable of long-term safe operation at 120% overload. It can operate at full load for a long time without forced air cooling in IP23 environment.
1. Superior Safety Performance
Non-combustible, self-extinguishing and non-toxic insulation materials, with extremely low combustible content, meeting the highest fire safety requirements for public and industrial buildings.
2. Excellent Environmental Adaptability
Outstanding three-proof performance (moisture-proof, mildew-proof, salt-fog-proof), suitable for high humidity, salt-fog and harsh environments, with zero cracking and zero partial discharge.
3. Long Service Life & Reliability
Noex® insulation system ensures stable performance throughout the service life, with strong mechanical strength to withstand short-circuit impact and long-term overload.
4. Strong Overload Capacity
Can operate safely at 120% overload for a long time, and maintain full load operation without forced air cooling in IP23 environment.
1. Basic Temperature Control Functions
2. Model Naming Rule (Temperature Controller): BWDK-5□□
| Symbol | Meaning |
|---|---|
| B | For transformer |
| W | Temperature component |
| D | Resistance type |
| K | Control type (X: Display type) |
| 5 | Temperature range 0-200℃ |
| First □ | Number of fans |
| Second □ | Fan current |
3. PC Interface Type Temperature Controller
The temperature control system collects temperature signals via PT100 thermistors embedded in low-voltage windings, displays each winding temperature intuitively, and supports computer interface for remote temperature monitoring.
4. Technical Parameters of Temperature Controller
| Item | Specification |
|---|---|
| Operating Temperature | -10℃ ~ +55℃ |
| Power Supply | AC220V ±10%, 50Hz |
| Measurement Range | 0~200℃ |
| Output Contact Capacity | AC220V, 3A |
| 额定容量 Rated capacity (kVA) |
电压组合及分接范围 Voltage combination and tap range (kV) |
联结组标号 connection symbol |
空载损耗 No load loss (KW) |
不同绝缘系统温度下的负载损耗 Temperature of different insulation systems Load loss below(KW) |
空载电流 No load current (%) |
短路阻抗 Short circuit impedance (%) |
重量 weight (kg) |
外形尺寸(mm) Dimensions (mm) (长L×宽B×高H) |
安装尺寸 installation size |
带外壳尺寸 With shell size (L×W×H) |
||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 高压 high pressure (kV) |
高压分接范围 High voltage division Range of acceptance (%) |
低压 low pressure (kV) |
130℃(B) (100℃) | 155℃(B) (120℃) | 180℃(B) (145℃) | |||||||||
| 100 | 6/6.3/6.6 10/10.5/11 |
±2.5 ±5 |
0.4 | Dyn11 Yyn0 |
0.36 | – | 1.69 | – | 1.5 | 4 | 590 | 850×600×830 | 400/450 | 1250×1000×2200 |
| 125 | 0.42 | – | 1.98 | – | 1.3 | 650 | 870×650×890 | 550/550 | 1300×1000×2200 | |||||
| 160 | 0.48 | – | 2.28 | – | 1.3 | 800 | 900×710×930 | 550/550 | 1300×1100×2200 | |||||
| 200 | 0.56 | – | 2.71 | – | 1.1 | 880 | 940×750×980 | 550/660 | 1350×1100×2200 | |||||
| 250 | 0.65 | – | 2.96 | – | 1.1 | 1050 | 990×770×1030 | 660/660 | 1400×1150×2200 | |||||
| 315 | 0.79 | – | 3.73 | – | 1 | 1260 | 1020×790×1080 | 660/660 | 1450×1150×2200 | |||||
| 400 | 0.88 | – | 4.28 | – | 1 | 1570 | 1060×880×1180 | 660/820 | 1450×1200×2200 | |||||
| 500 | 1.04 | – | 5.23 | – | 1 | 1780 | 1090×900×1220 | 660/820 | 1500×1200×2200 | |||||
| 630 | ±2×2.5 ±5 |
1.17 | – | 6.4 | – | 0.85 | 6 | 1860 | 1200×920×1150 | 820/820 | 1600×1200×2200 | |||
| 800 | 1.37 | – | 7.46 | – | 0.85 | 2180 | 1260×920×1200 | 820/820 | 1650×1200×2200 | |||||
| 1000 | 1.59 | – | 8.76 | – | 0.85 | 2590 | 1320×950×1250 | 820/820 | 1750×1300×2200 | |||||
| 1250 | 1.88 | – | 10.3 | – | 0.85 | 2980 | 1350×980×1320 | 820/820 | 1750×1350×2200 | |||||
| 1600 | 2.2 | – | 12.5 | – | 0.85 | 3580 | 1400×1120×1400 | 1070/1070 | 1800×1400×2200 | |||||
| 2000 | 2.75 | – | 15.5 | – | 0.7 | 4070 | 1440×1120×1520 | 1070/1070 | 1850×1450×2200 | |||||
| 2500 | 3.24 | – | 18.4 | – | 0.7 | 4820 | 1500×1120×1640 | 1070/1070 | 1900×1500×2200 | |||||