CM3 MCCB Molded-Case-Circuit-Breaker 63A-800A

The CM3 series molded case circuit breakers are mainly applicable to AC 50Hz circuits with a rated working voltage up to 400V and a rated working current up to 800A, CM3 (M3) is a new generation of high-performance molded case circuit breaker, complying with GB 14048.2 and IEC 60947-2 standards. It is used for overload, short circuit and under-voltage protection of power distribution lines and equipment in AC 50Hz systems.

With compact structure, high breaking capacity, stable performance and long service life, CM3 series is widely used in power distribution, industrial control, construction engineering, data centers and other fields.

CM3 (M3) Series Molded Case Circuit Breaker – Overview

Model Frame Current Voltage Application
CM3-6363AAC 400VLight distribution, small equipment
CM3-100100AAC 400VWorkshop, small building
CM3-225225AAC 400VCommercial power, small industry
CM3-400400AAC 400VIndustrial distribution
CM3-630630AAC 400VHeavy equipment, main line
CM3-800800AAC 400VLarge power distribution

Main Technical Parameters

CM3 (M3) Series MCCB – Detailed Technical Parameters

Item CM3-63 CM3-100 CM3-225 CM3-400 CM3-630 CM3-800
Frame Current Inm (A) 63 100 225 400 630 800
Rated Current In (A) (6),10,16,20,25,32,40,50,63 10,16,20,32,40,50,63,80,100 100,125,160,180,200,225 225,250,315,350,400 400,500,630 630,700,800
Rated Insulation Voltage Ui (V) 500 690 800 690 690 690
Rated Operating Voltage Ue (V) 400 400 230/400 400 400 400
Rated Impulse Withstand Voltage Uimp (kV) 6 6 8 6 6 6
No. of Poles 3/4 3/4 2/3/4 3/4 3/4 3/4
Breaking Class L/M L/M L/M/H L/M L/M L/M
Ultimate Breaking Capacity Icu (kA) AC400V 10/15/35 35/50 35/50/65 45/65 45/65 50/65
Service Breaking Capacity Ics (kA) AC400V 5/10/25 25/30 25/30/50 22.5/32.5 22.5/32.5 25/32.5
Arc Flash Distance (mm) ≤50 ≤50 ≤50 ≤100 ≤100 ≤100
Operating Cycles / Hour 120 120 120 60 60 20
Mechanical Life With Load 4000 3000 3000 1500 1500 1000
Mechanical Life No Load 6000 7000 7000 6500 6500 4000
Tripping Type Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic Thermal-magnetic
Protection Class IP30 IP30 IP30 IP30 IP30 IP30
Standards GB14048.2, IEC60947-2 GB14048.2, IEC60947-2 GB14048.2, IEC60947-2 GB14048.2, IEC60947-2 GB14048.2, IEC60947-2 GB14048.2, IEC60947-2

CM3 (M3) Series – Core Features

  • High breaking capacity up to 70kA
  • Compact and reliable structure
  • Thermal-magnetic tripping for accurate protection
  • 3P and 4P for wide application
  • Fixed and plug-in installation available
  • Flame retardant shell, high safety
  • Long mechanical and electrical life

CM3 (M3) Series – Typical Applications

Industrial Power Distribution
Commercial Building Power
Motor & Pump Protection
Construction Engineering
Data Center Auxiliary Power
Infrastructure Projects